Carrier Manuals Service

Carrier Manuals Service 3,9/5 1836 reviews
  1. Carrier Parts Manual
  2. Carrier Hvac Manuals
  3. Carrier Thermostat Manual

.Residential Fan Coil Units Visit www.carrier.com Service Manual TABLE OF CONTENTS Page SAFETY CONSIDERATIONS.2 INTRODUCTION.2 UNIT IDENTIFICATION.2 PRODUCT OFFERING.4 FAN MOTOR SPEED TAPS.4 FA4A, FB4A, FC4B, FF1D, FH4A, AND FX4A CIRCUIT BOARD FUNCTION AND TROUBLESHOOTING — CES013003-00 and -01 PCB.2-7.This symbol → indicates a change since the last issue. A 5-amp fuse is used to protect the low-voltage transformer secondary. SAFETY CONSIDERATIONS 3. The fan relay is controlled by thermostat and turns fan on and Improper installation, adjustment, alteration, service, maintenance, off.Table 1—Product Offering MODEL UNIT SIZE DESCRIPTION CABINET FA4ANF 018-060 Multipoise Single Piece FB4ANB 042-070 Multipoise Modular FB4ANF 018-060 Multipoise Single Piece Multipoise FB4ASB 042-060 Modular 50 Hz Multipoise FB4ASF 018-060 Single Piece 50 Hz FC4BNB 042-070 Multipoise Modular FC4BNF.VOLTAGE PCB BLOCK WIRING FUSE TIME DELAY FUSE LR40061 FAN RELAY A97020 Fig. 3A—Fan Coil Printed-Circuit Board 3. Check field power leads L1 and L2. If these are not receiving 2.

Carrier Parts Manual

Check sequencer/relay number 1 and plug wiring. Yellow power, system cannot function. Wire should be connected to pin number 9 of plug and to limit switch.CAUTION: SCHEMATIC DIAGRAM NOT SUITABLE FOR USE ON SYSTEMS EXCEEDING 150V TO GROUND SEE RATING PLATE FOR VOLTS & HERTZ ATTENTION: FIELD POWER WIRING NE CONVIENT PAS AUX INSTALLATIONS DE PLUS DE 150 V A LA TERRE COOLING CONTROLS COMPONENT ARRANGEMENT ELECTRIC HEAT SEE NOTE #1 DISCONNECT PER NEC.WARNING ELECTRIC SHOCK HAZARD DISCONNECT REMOTE POWER SUPPLY BEFORE OPENING PANEL. PULL TO OPEN RELAY 322861-101 REV. A FF1D CONTROL BOX WARNING ELECTRIC SHOCK HAZARD DISCONNECT REMOTE POWER SUPPLY BEFORE OPENING PANEL. PULL TO OPEN 322861-101 REV.

Product

The Carrier 30GX has a compact design that is up to 50% smaller than existing coolers. The Carrier 30GX is supplied as a complete package for easy installation. The 30GX also provides a single electrical input (using the optionally installed on factory installed power transformer or an accessory field) and quick and easy pipe using clamp couplings type VIC standard aulic or welded standard for the cooler. Ensures a quick start commissioning after installation, since each unit 30GX is manufactured in an ISO 9002 listed manufacturing plant to guarantee the quality. In addition, all units are factory full load testing to provide a setting up reliable. 30GX units have a design quiet, low-vibration with compression screws rotating and new 'aero-acoustic' fans that reduce sound levels and improve the quality of the sound. The Carrier 30GX controls are fully automatic. Output fluid temperature is controlled directly, and the fluid inlet temperature is continuously monitored to detect changes of load and flow. This combination (an exclusive advantage of Flotronic controls) provides temperature control more precise available.

Carrier Manuals Service

Carrier Hvac Manuals

Air

Carrier Thermostat Manual

In addition, 30GX units can handle fast and slow loading applications. All coolers air-cooled 30GX with ECOLOGIC controls are ready to connect them to the network Carrier Comfort Network (CCN) systems or can be used in independent operations. In addition, with the standard accessories control module, ECOLOGICAL coolers can accept signals limit demand, point dual setpoint and temperature of outside air through a connection of 4 to 20 mA, which makes them ideal for applications of feedback with an existing building management system.